CommMonitor - Modbus View Function and Properties
CommMonitor Modbus View Functions and Features
1. The Modbus View is primarily designed to analyze serial port monitored data using the Modbus protocol, breaking down Modbus data packets. It supports both RTU and ASCII modes.
Related options can be configured.

2. Column Descriptions:
ID: Modbus protocol header ID
Function Code: Modbus protocol function code
Address: Starting address for reading/writing coils or registers
Quantity: Number of coils or registers being read/written
Data: Content of the read/write request for coils or registers. Data content is parsed according to the specific function code
CRC Check: CRC verification result - Pass or Fail
COM: Corresponding COM port
Timestamp: Monitoring record time, based on option settings
Mode: RTU or ASCII
Remark: Response or Request